PAGE 9IN400 INSTALLATION AND OPERATION MANUALDIMENSIONS
PAGE 10 IN400 INSTALLATION AND OPERATION MANUALSPECIFICATIONSPOWER OUTPUT (0.5%THD, 1kHz) 8ohm 50W, 4ohm 80WTHD (20-10kHz, 8ohm, -2dBr)
SYDNEY(NSW SALES)1 Clyde StreetSilverwaterNSW 2128Private Bag 149Silverwater NSW 1811Phone: (02) 9647 1411Fax: (02) 9648 3698Email:[email protected].
11223344D DC CB BA AVGA-ENVGA-SDVGA-A0VGA-A1Composite Switching & Main Board ConnectionCD6383-1-B.SchDocVGA-ENVGA-SDVGA-A0VGA-A1RGBHV Switch
11223344D DC CB BA AVGND -5VDC40.1uFVGNDIN13IN25IN37IN01GND2GND4V-6V+14A19A08EN10FB12OUT13SD11U2LMH6574MAC30.1uF+5VDR151k5VGNDD1PGB1010603R1775D3PGB10
1122334455667788D DC CB BA AIN13IN25IN37IN01GND2GND4V-6V+14A19A08EN10FB12OUT13SD11U4LMH6574MA1OE1B21C331C241C151C06Y17GND8Y292C0102C1112C2122C313A142O
1122334455667788D DC CB BA AR1310kC10.1uFC910uF12345678910To Main PCBCN1+5VGNDFP-SCLFP-SDASDA23SCL22A021A12A23GND12VCC24INT1IO0.04IO0.15IO0.26IO0.37
1122334455667788D DC CB BA ANC2+V5NC6NC111093+V1-V4GND7MUT8U1LM3886TFR2100kC310uF BP-35V+35VC847uFGNDC60.1uFC247uFGNDC10.1uFC547uFGNDR522kR816kC9220p
1122334455667788D DC CB BA ASPI-MOSISPI-CSSPI-SCKAMP1-MUTEAMP2-MUTECTRL-INCTRL-ADOUT2-MUTEOUT1-MUTEAudio SwitchingCD07900-1-E.SchDocRS485-ARS485-BCTR
1122334455667788D DC CB BA AINPUT 1 L56INPUT 1 RCN1BC110uF BPC1110uF BPR2470R8470R722kR422k0VMAININPUT 2 LINPUT 2 RCN1AC1410uF BPC2110uF B
IN400AV SWITCHING AMPLIFIERINSTALLATION AND OPERATION MANUAL
1122334455667788D DC CB BA AVDD17VDDAD29VREFH34VSS16VSS39VSSAD30VREFL35XTAL/PTG537EXTAL/PTG638RST3IRQ2BKGD/MS36PTA021PTA122PTB0/AD1P023PTB1/AD1P124PTB
1122334455667788D DC CB BA A0VMAINC62470uFC71470uF4136DB1DB104C6010nFC6110nFC6910nFC7010nFVPOSVNEG0VAMPC843300uF2134DB2GBU8GC7610nFC7710nFC8210nFC8310
TEST PROCEDURE IN400 Revision Date Comments A 22nd May 2008 Original B 6th May 2008 Changed some signal gen sensitvities. Outline 1. Physical
Test Procedure VISUAL INSPECTION STAGE 1. Physical checks • All screws for tightness, referring to the torque setting of the manufacturing tools
Ensure that power is applied to the unit. On first power-up, all front panel indicators should be OFF. (P/F) Press the power button. The power LED sh
Setup Signal generator = 350mVAC, Sine, 1kHz Signal input = DVD1, right channel RCA input Power state of unit: ON Selected source on unit: DVD
FINAL TESTING REQUIREMENTS FOR FINAL TESTING: a) THD meter b) Signal generator c) Load 8ohm d) Multimeter e) Oscilloscope f) Variac 240VAC, vo
Signal generator = 300mVAC, Sine, 1kHz Signal input = DVD1, left channel RCA input Power state of unit: ON Selected source on unit: DVD1 Volum
Set volume on unit to max by rotating the volume control CW until the highest LED is lit. (P/F) The residual noise floor should be <1mV. Values t
13a. A/V Test DVD1 Pass 13b. A/V Test DVD2 Pass 13c. A/V Test AUX1 Pass 13d. A/V Test AUX2 Pass 13.2. Sources AUX3, AUX4, PC1, PC2
Read these instructions.1. Keep these instructions.2. Heed all warnings.3. Follow all instructions.4. Do not use this apparatus near water.5. Clean on
[Setup for next test] Set the frequency back to 1kHz. 15. Non-Volatile Memory Setting Procedure Ensure power to the unit is ON. Press the power bu
LISTENING TEST REQUIREMENTS FOR LISTENING TEST SETUP: a) CD Player b) 2x Speakers 18. Listening Test Connect unit to mains power (240VAC). Conn
PAGE 3IN400 INSTALLATION AND OPERATION MANUALThe Innovation series from AMAV is a huge step forward in the interfacing and management of audio and vis
PAGE 4 IN400 INSTALLATION AND OPERATION MANUALFRONT PANEL3 15 74 26 81 MASTER VOLUMEThis pot controls the audio output level.2 MASTER VOLUME LEDSThese
PAGE 5IN400 INSTALLATION AND OPERATION MANUALREAR PANEL1 AUDIO INPUTSourcesThese are the RCA unbalanced line level audio inputs for each of the 8 sour
PAGE 6 IN400 INSTALLATION AND OPERATION MANUALSETUPData CommandsCOMMS DESCRIPTION!VER:???<CR> Version request. Device replies with !VER=xyz whe
PAGE 7IN400 INSTALLATION AND OPERATION MANUALINSTALLATIONPOWER CONNECTIONEnsure the mains voltage supply matches the rear of the IN400 (+/- 10%)Ensure